国产日韩欧美_国产亚洲一卡2卡3卡4卡网站_国产亚洲精品综合网在线观看_国产亚洲成AⅤ人片在线奶水_国产下药迷倒白嫩美女在线_国产午夜精品一区二E1_日本国产制服丝袜一区

產(chǎn)品列表PRODUCTS LIST

首頁>產(chǎn)品中心>日本光明北川式氣體檢測管>氣體快速檢測管>105SD戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm

戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm

簡要描述:

戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm,通過直接讀取方式,可簡單測定空氣中各種氣體的濃度。使用1個檢測器(泵),只要更換檢測管,就能進行測定。由于是直接讀取式,所以不會出現(xiàn)人為誤差。1沖程(100ml)30~120秒,就可以結(jié)束濃度測定。

更新時間:2024-12-26

發(fā)郵件給我們:554328895@qq.com

分享到: 1
在線留言
戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm

戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm

Tube 05SD
1. PERFORMANCE
1) Measuring range :1-20 ppm 0.2-1 ppm
Number of pump strokes 1(100ml) 5(500ml)
2) Sampling time :1 minute/1 pump stroke
3) Detectable limit :0.1 ppm(100ml)
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Reading :Direct reading from the scale calibrated by 1 pump stroke
7) Colour change :Pale purple→Pale Yellow
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:5% RSD-high:5%
3. CHEMICAL REACTION
By reacting with Phosphoric acid, PH indicator is discoloured.
2NH3+H3PO4→(NH4)2PO4
4. CALIBRATION OF THE TUBE
PERMEATION TUBE METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
20
18
16
14
12
10
8
6
4
2 1
100ml
ppm
GAS To pump
DEHUMIDIFIER
(White)
105SD AMMONIA
Substance Interference Coexistence
Amines Similar stain is produced. Higher readings are given.
(NOTE)
When the concentration is below 1 ppm, 2 to 5 pump strokes can be used to detemine the lower concentration.
Following formula is available for actual concentration.
Actual concentration=Reading value× 1
Number of strokes

The KITAGAWA Gas Detector Tube System is a complete sampling and analysis system for determining hazardous gas and vapour concentrations quickly and easily. The KITAGAWA Gas Detector Tube System is comprised of an Air Sampling Pump and Precision Gas Detector Tubes.

The KITAGAWA air sampling pump reproducibly draws 100cc of sample air through the detector tube. All detector tubes are calibrated for a single pump stroke; there is no need for multiple volumes or stroke counters.

Each detector tube is formulated with high purity reagents that absorb and react with the target gas or vapour being measured. A colorimetric stain is created that is proportional in length to the concentration. For most tubes, the concentration is read directly off the measurement scale on each tube. 
 How To Use The KITAGAWA Gas Detector Tube System 
 
Detector tubes are available to measure more than 200 different kinds of gases and vapours. For many gases and vapours, there are several concentration ranges available giving you the flexibility to measure both low and high concentrations without sacrificing precision.

For specific information, please refer to the list of detector tubes.